NABL 17025 accredited laboratory for all types of pile tests - Static vertical pile load test, Lateral load test, Pullout test, Low strain pile integrity test, High strain dynamic pile load test and crosshole sonic test.

Struct Geotech Research Laboratories Pvt. Ltd.

Dynamic Pile Monitoring
It is conducted during the impact driving of steel, concrete or timber piles to contribute to safe and economical pile installation. Most important results of this test are soil resistance to driving, hammer performance, dynamic pile stresses during driving and pile integrity.

Soft ware used is CAse Pile Wave Analysis Program (CAPWAP) – Determines

  • Static soil resistance
  • Simulates a static load test
  • Static shaft resistance
  • Magnitude and distribution
  • Static end bearing
  • Stresses at any point along the shaft
  • Energy transferred from the ram to the foundation.

Benefits at a Glance :

  • Evaluates the bearing capacity of driven piles, drilled shafts and auger cast(CFA) piles
  • Tests deep foundation integrity quickly and economically
  • Checks pile stresses and hammer performance
    Used worldwide for more than 30 Years
  • Proven reliable on thousands of construction sites
    Specified by Engineers, Contractors, Government agencies
  • Conforms to international standards and ASTM D4945.

Recognition

Dynamic testing is officially recognized by:
American Society for Testing Materials (ASTM)

  • Deep Foundations Institute(DFI)
  • Pile Driving Contractors Association (PDCA)
  • American Society of Civil Engineers (ASCE)
  • Federal Highway Administration (FHWA)
  • American Association of State Highway Transportaion Officials (AASHTO)
  • Many U.S. State Highway departments
  • U.S.Army Corps of Engineers
    International Building Code (IBC 2000)
  • Numerous International Organizations
  • Pile Integrity Testing/ Low strain Integrity Testing
  • Dynamic Pile Testing/ High strain dynamic pile analyzer
  • Static pile load testing:
  • Kenteledge load test Method
  • Reaction beam load test
  • Method/ Rock Anchoring Method
  • Lateral load test
  • Pullout load test
  • Bi-Directional load testing

Pile integrity Tester (PIT) performs Low Strain Integrity Testing,. Conforms to ASTM D5882 & various codes worldwide
Can be used for :

  • Detection of potentially dangerous defects such as major cracks, necking, soil inclusions or voids
    Integrity of pile in its total length
  • Can determine unknown length of pile that support existing bridges or towers

High Strain Dynamic Pile Testing
Dynamic Load Testing is conducted independent of pile installation process. The test has primary goal of assessment of bearing capacity . It is applicable to drilled shafts, continuous flight auger, Cast-in-situ and driven piles

What We Do

Contact us

# 588, 2nd Main, 6th Block,
Hosekerehalli Cross,
Banashankari 3rd Stage, 2nd Phase,
Bangalore 560 085
Karnataka State, India
Ph: +91 80 26422752 / 2672 3662 /
2642 3632
E-Mail: sgrlpl@yahoo.com,
enquiry@structgeotech.com

Our Clients

bmrcl
L&T2
Simplex-infra
bial
Airports-authority
RITES-INDIA
itd-cem
ashok-build-con
gr-infra
ncc

Copyright © 2020. Struct Geotech Research Laboratories Pvt. Ltd.